Use
DL - 10 series of current relays, electromagnetic transient had current relay. It is widely used in electric power system secondary circuit of relay protection device in the line, as a current starting element.
Main technical parameters
The action time: 1.1 times the actual action value, the action time is not more than 0.12s;
When the measured action of 2 times, the action time is no more than 0.04s.
|
|
Type number
|
Maximum integer Fixed value |
Setting range
|
Coil series
|
Coil parallel
|
Power Consumption |
Contact number
|
Return coefficient
|
|
Action current
|
Action current
|
Moving
|
Dynamic break
|
|||||
DL—11
|
0.01A
|
0.0025~0.01A
|
0.0025~0.005A
|
0.005~0.01A
|
≤7VA
|
1
|
|
≥0.8
|
DL—12
|
|
1
|
||||||
DL—13
|
1
|
1
|
||||||
DL—11
|
0.04A
|
0.01~0.04A
|
0.01~0.02A
|
0.02~0.04A
|
≤7VA
|
1
|
|
|
DL—12
|
|
1
|
||||||
DL—13
|
1
|
1
|
||||||
DL—11
|
0.05A
|
0.0125~0.05A
|
0.0125~0.025A
|
0.025~0.05A
|
≤7VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
1
|
||||||
DL—11
|
0.2A
|
0.05~0.2A
|
0.05~0.1A
|
0.1~0.2A
|
≤7VA
|
1
|
1
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
0.6A
|
0.15~0.6A
|
0.15~0.3A
|
0.3~0.6A
|
0.5~1A
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
2A
|
0.5~2A
|
0.5~1A
|
1~2A
|
≤3.5VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
6A
|
1.5~6A
|
1.5~3A
|
3~6A
|
≤3.5VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
10A
|
2.5~10A
|
2.5~5A
|
5~10A
|
≤3.5VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
15A
|
3.75~15A
|
3.75~7.5A
|
7.5~15A
|
≤3.5VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
20A
|
5~20A
|
5~10A
|
10~20A
|
≤3.5VA
|
1
|
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
1
|
||||||
DL—11
|
50A
|
12.5~50A
|
12.5~25A
|
25~50A
|
≤3.5VA
|
1
|
1
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
1
|
||||||
DL—11
|
100A
|
25~100A
|
25~50A
|
50~100A
|
≤3.5VA
|
1
|
1
|
|
DL—12
|
|
|
||||||
DL—13
|
1
|
|
||||||
DL—11
|
200A
|
50~200A
|
50~100A
|
100~200A
|
≤3.5VA
|
1
|
1
|
≥0.7
|
DL—12
|
|
1
|
||||||
DL—13
|
1
|
1
|
Contact capacity: |
No more than 250V voltage, the electric current does not exceed 5a, the time constant for 5 + 0.75ms DC sense circuit load, product output contact breaking capacity is 50W. The output contacts in the above specified load conditions, the product can act reliably and return 5 * 104 times. The output contact allows for a long time 5A. Dielectric strength: products of each conductive terminal even together, on the exposed uncharged metal part or between the shell, bear 2000V (RMS) 50Hz AC voltage which lasted 1 minute test without dielectric breakdown or flashover phenomenon. |