TEL:0577-62755833
http://www.ccjdq.com
Current position:Home » Products » Current relay » Products

Products

Current relay DL-10 series

Current relay DL-10 series



Use

DL - 10 series of current relays, electromagnetic transient had current relay. It is widely used in electric power system secondary circuit of relay protection device in the line, as a current starting element.

Main technical parameters

The action time: 1.1 times the actual action value, the action time is not more than 0.12s;

When the measured action of 2 times, the action time is no more than 0.04s.


  • Type number

    Maximum integer

    Fixed value

    Setting range
    Coil series
    Coil parallel

    Power

    Consumption

    Contact number
    Return coefficient
    Action current
    Action current
    Moving
    Dynamic break
    DL—11
    0.01A
    0.0025~0.01A
    0.0025~0.005A
    0.005~0.01A
    ≤7VA
    1
    ≥0.8
    DL—12
    1
    DL—13
    1
    1
    DL—11
    0.04A
    0.01~0.04A
    0.01~0.02A
    0.02~0.04A
    ≤7VA
    1
    DL—12
    1
    DL—13
    1
    1
    DL—11
    0.05A
    0.0125~0.05A
    0.0125~0.025A
    0.025~0.05A
    ≤7VA
    1
    DL—12
    DL—13
    1
    1
    DL—11
    0.2A
    0.05~0.2A
    0.05~0.1A
    0.1~0.2A
    ≤7VA
    1
    1
    DL—12
    DL—13
    1
    DL—11
    0.6A
    0.15~0.6A
    0.15~0.3A
    0.3~0.6A
    0.5~1A
    1
    DL—12
    DL—13
    1
    DL—11
    2A
    0.5~2A
    0.5~1A
    1~2A
    ≤3.5VA
    1
    DL—12
    DL—13
    1
    DL—11
    6A
    1.5~6A
    1.5~3A
    3~6A
    ≤3.5VA
    1
    DL—12
    DL—13
    1
    DL—11
    10A
    2.5~10A
    2.5~5A
    5~10A
    ≤3.5VA
    1
    DL—12
    DL—13
    1
    DL—11
    15A
    3.75~15A
    3.75~7.5A
    7.5~15A
    ≤3.5VA
    1
    DL—12
    DL—13
    1
    DL—11
    20A
    5~20A
    5~10A
    10~20A
    ≤3.5VA
    1
    DL—12
    DL—13
    1
    1
    DL—11
    50A
    12.5~50A
    12.5~25A
    25~50A
    ≤3.5VA
    1
    1
    DL—12
    DL—13
    1
    1
    DL—11
    100A
    25~100A
    25~50A
    50~100A
    ≤3.5VA
    1
    1
    DL—12
    DL—13
    1
    DL—11
    200A
    50~200A
    50~100A
    100~200A
    ≤3.5VA
    1
    1
    ≥0.7
    DL—12
    1
    DL—13
    1
    1
Contact capacity:

No more than 250V voltage, the electric current does not exceed 5a, the time constant for 5 + 0.75ms DC sense circuit load, product output contact breaking capacity is 50W. The output contacts in the above specified load conditions, the product can act reliably and return 5 * 104 times. The output contact allows for a long time 5A.

Dielectric strength: products of each conductive terminal even together, on the exposed uncharged metal part or between the shell, bear 2000V (RMS) 50Hz AC voltage which lasted 1 minute test without dielectric breakdown or flashover phenomenon.

  • Internal connection



© 2015 Shanghai A Cheng Electric Co. Ltd. All Rights Reserved.