TEL:0577-62755833
http://www.ccjdq.com
Current position:Home » Products » Current relay » Products

Products

Current relay JL-30 series

Current relay JL-30 series


    • Use

      JL series integrated circuit current relay (hereinafter referred to as "the product") for motor, transformer and transmission line overload and short-circuit protection device as a starting element. This product for the static type of integrated circuit relay, high precision, low power consumption, short action time, return coefficient is high, the setting is intuitive, convenient, it overcomes the original type electromagnetic relay contacts are easily jitter, noise larger, action of return coefficient is difficult to adjust and transport action value liable to change the disadvantages of value of. The products are divided into three series: JL-10, JL-20, JL-30, DL-10, DL-20, can replace DL-30, DL-7 electromagnetic relay.

      Model


    Note: JL, 10, 20, 30 series of current relays and other various types of factory JL - 1A, 1b, 1C, JL8 - 10, 20, 30 series belong to the products of the same type.

    Main technical data


    Auxiliary power supply: DC 220V、110V、48V;
    Setting range: See model description
    Setting error: In the baseline condition, the setting value of the error is less than + 2.5%; consistency is not greater than 1.5%
    Return coefficient: In the baseline condition, return any set point value of not less than 0.9;
    Action time: 1.1 times the setting action time is no more than 25ms.
    Return time: 0.5 times the setting time of the return is no more than 27ms.
    Power consumption: The power consumption of AC circuit is less than 2VA and the power consumption of DC loop is less than 5W.
    Contact capacity: No more than 250V voltage, the electric current does not exceed 5a, the time constant for 5 + 0.75ms DC sense circuit load, product output contact breaking capacity is 50W. The output contacts in the above specified load conditions, the product can act reliably and return 5 * 104 times. The output contact allows for a long time 5A.
    Medium strength: Products of each conductive terminal even together, on the exposed uncharged metal part or between the shell, bear 2000V (RMS) 50Hz AC voltage which lasted 1 minute test without dielectric breakdown or flashover phenomenon.
    • Internal wiring diagram


    Note:

    JL-1A same as JL-11

    JL-1B same as JL-21

    JL-1C same as JL-31



© 2015 Shanghai A Cheng Electric Co. Ltd. All Rights Reserved.