For the automatic control device, the control circuit is to expand and improve.
Rated voltage: |
DZ - 51, DZ - 53 DC: 220V, 110V, 48V, 24V, 12V. DZ - 52, DZ - 54 : 380V, 220V, AC 110V, 48V, 36V, 24V, 12V. JY - 16A DC: 220V, 110V, 48V, 24V, 12V. : 380V, 220V, AC 110V, 48V, 36V, 24V, 12V. |
Contact form: |
DZ - 51, DZ - 52: 4 (400), close 2 2 break (220), 4 (040), 2 break switch (002). DZ - 53, DZ - 54: 8 (800), close 6 2 break (620), 4 close (400), 4 4 break (440) etc.. JY - type 16A: 4 (400), close 2 2 (220), 4 break break (040), 2 2 (202), 2 conversion moveoff 2 conversion (022), 2 (002) conversion. |
Operating voltage: |
AC relay is not more than 85% of the rated voltage; rated voltage DC relay is not greater than 70%. |
The action time: | Under rated voltage, operating time is less than 0.03s. |
Contact capacity: | No more than 250V voltage, the electric current does not exceed 5a, the time constant for 5 + 0.75ms DC sense circuit load, product output contact breaking capacity is 50W. The output contacts in the above specified load conditions, the product can act reliably and return 5 * 104 times. The output current is 5A connected to allow long-term contact. |
Power consumption: | Under rated voltage, the DC relay is not greater than 2.5W; AC relay is not greater than 5VA. |
Internal wiring diagram
Note: DZ-53, DZ-54 is a non shell type relay.